Skip to content
Documentation Menu

TC_004_1_CS — Regular Charging Session – Identification First

TC_004_1_CS — Regular Charging Session – Identification First

Source: OCPP 1.6 — Compliancy Testing Tool — Test Case Document (Trial 2025-06, Draft). System Under Test: Charge Point, page 9.

Identification

FieldValue
Test case nameRegular Charging Session – Identification First
Test case IdTC_004_1_CS
System under testCharge Point

Description

This scenario is used to start a Charging session.

Purpose

To test if the Charge Point is able to start a Charging Session when first doing authorization.

Prerequisite(s)

  • N/a

Before (Preparations)

Configuration State(s):

  • Value for "MeterValueSampleInterval" is <Configured Meter Value interval>.

Memory State(s):

  • N/a

Reusable State(s):

  • N/a

Scenario Detail(s)

Charge Point (SUT)Central System (Tool)
1. Execute Reusable State Authorized
2.Manual Action: EV driver plugs in the cable.
3. The Charge Point sends a StartTransaction.req4. The Central System responds with a StartTransaction.conf
5. The Charge Point sends a StatusNotification.req6. The Central System responds with a StatusNotification.conf
Note: Step 3 and step 5 may be reversed.

Tool validation(s)

Charge Point side:

Step 5:

(Message: StatusNotification.req) status is Charging

Central System side:

Step 4:

(Message: StartTransaction.conf) idTagInfo.status is Accepted

Expected result(s) / behaviour

Charge Point side:

  • N/a

Central System side:

  • N/a