Skip to content
Documentation Menu

TC_024_CSMS — Start Charging Session Lock Failure

TC_024_CSMS — Start Charging Session Lock Failure

Source: OCPP 1.6 — Compliancy Testing Tool — Test Case Document (Trial 2025-06, Draft). System Under Test: Central System, page 142.

Identification

FieldValue
Test case nameStart Charging Session Lock Failure
Test case IdTC_024_CSMS
System under testCentral System

Description

This scenario is used to report a connector lock failure.

Purpose

To test if the Central System is able to handle a report of a connector lock failure.

Prerequisite(s)

  • N/a

Before (Preparations)

Configuration State(s):

  • N/a

Memory State(s):

  • N/a

Reusable State(s):

  • Authorized

Scenario Detail(s)

Charge Point (SUT)Central System (Tool)
1. The Charge Point sends a StatusNotification.req2. The Central System responds with a StatusNotification.conf
[EV driver plugs in the cable.]; 3. The Charge Point sends a StatusNotification.req4. The Central System responds with a StatusNotification.conf

Tool validation(s)

Charge Point side:

Step 1:

(Message: StatusNotification.req) status is Preparing

Step 3:

(Message: StatusNotification.req) errorCode is ConnectorLockFailure status is Faulted

Central System side:

  • N/a

Expected result(s) / behaviour

Charge Point side:

  • N/a

Central System side: