TC_034_CS — Power Failure with Unavailable Status

TC_034_CS — Power Failure with Unavailable Status

Source: OCPP 1.6 — Compliancy Testing Tool — Test Case Document (Trial 2025-06, Draft). System Under Test: Charge Point, page 45.

Identification

FieldValue
Test case namePower Failure with Unavailable Status
Test case IdTC_034_CS
System under testCharge Point

Description

This scenario is used to persist the status of the connectors, when a power failure occurs.

Purpose

To test if the Charge Point persists the status of the connectors, when a power failure occurs.

Prerequisite(s)

  • N/a

Before (Preparations)

Configuration State(s):

  • N/a

Memory State(s):

  • N/a

Reusable State(s):

  • N/a

Scenario Detail(s)

Charge Point (SUT)Central System (Tool)
2. The Charge Point responds with a ChangeAvailability.conf1. The Central System sends a ChangeAvailability.req
[Send per connector and connectorId = 0.]; 3. The Charge Point sends a StatusNotification.req4. The Central System responds with a StatusNotification.conf
[Disconnect and reconnect the power of the Charge Point.]; 5. The Charge Point sends a BootNotification.req6. The Central System responds with a BootNotification.conf
[Send per connector and connectorId = 0.]; 7. The Charge Point sends a StatusNotification.req8. The Central System responds with a StatusNotification.conf

Tool validation(s)

Charge Point side:

Step 2:

(Message: ChangeAvailability.conf) The status is Accepted

Step 3:

(Message: StatusNotification.req) status is Unavailable

Step 7:

(Message: StatusNotification.req) status is Unavailable

Central System side:

Step 1:

(Message: ChangeAvailability.req) The connectorId is 0 The type is Inoperative

Step 6:

(Message: BootNotification.conf) status is Accepted

Expected result(s) / behaviour

Charge Point side:

  • N/a

Central System side:

  • N/a