TC_040_2_CS — Configuratoin key - Invalid value

TC_040_2_CS — Configuratoin key - Invalid value

Source: OCPP 1.6 — Compliancy Testing Tool — Test Case Document (Trial 2025-06, Draft). System Under Test: Charge Point, page 53.

Identification

FieldValue
Test case nameConfiguratoin key - Invalid value
Test case IdTC_040_2_CS
System under testCharge Point

Description

This scenario is used to reject setting a configuration key, when an incorrect value is given.

Purpose

To test if the Charge Point is able to reject setting a configuration key, when an incorrect value is given.

Prerequisite(s)

  • N/a

Before (Preparations)

Configuration State(s):

  • N/a

Memory State(s):

  • N/a

Reusable State(s):

  • N/a

Scenario Detail(s)

Charge Point (SUT)Central System (Tool)
2. The Charge Point responds with a ChangeConfiguration.conf OR; with a CallError.1. The Central System sends a ChangeConfiguration.req

Tool validation(s)

Charge Point side:

Step 2:

(Message: ChangeConfiguration.conf) The status is Rejected OR (Message: CallError ErrorCode is PropertyConstraintViolation.

Central System side:

Step 1:

(Message: ChangeConfiguration.req) The key is MeterValueSampleInterval value is -1

Expected result(s) / behaviour

Charge Point side:

  • N/a

Central System side:

  • N/a