TC_055_CS — Trigger Message - Rejected
TC_055_CS — Trigger Message - Rejected
Source: OCPP 1.6 — Compliancy Testing Tool — Test Case Document (Trial 2025-06, Draft). System Under Test: Charge Point, page 80.
Identification
| Field | Value |
|---|---|
| Test case name | Trigger Message - Rejected |
| Test case Id | TC_055_CS |
| System under test | Charge Point |
Description
The Central System triggers a message from the Charge Point, but the Charge Point rejects the message.
Purpose
Check whether the Charge Point is able to reject a message triggered by the Central System.
Prerequisite(s)
The Charge Point supports the Remote Trigger feature profile.
Before (Preparations)
Configuration State(s):
- N/a
Memory State(s):
- N/a
Reusable State(s):
- N/a
Scenario Detail(s)
| Charge Point (SUT) | Central System (Tool) |
|---|---|
| 2. The Charge Point responds with a TriggerMessage.conf OR; with a CallError | 1. The Central System sends a TriggerMessage.req |
Tool validation(s)
Charge Point side:
Step 2:
(Message: TriggerMessage.conf)
- status is Rejected
Central System side:
Step 1:
(Message: TriggerMessage.req)
- requestMessage is MeterValues
- connectorId is configured NumberOfConnectors + 1
Expected result(s) / behaviour
Charge Point side:
The Charge Point does not send the message that was requested by the Central System.
Central System side:
- N/a