Skip to content
Documentation Menu

TC_055_CS — Trigger Message - Rejected

TC_055_CS — Trigger Message - Rejected

Source: OCPP 1.6 — Compliancy Testing Tool — Test Case Document (Trial 2025-06, Draft). System Under Test: Charge Point, page 80.

Identification

FieldValue
Test case nameTrigger Message - Rejected
Test case IdTC_055_CS
System under testCharge Point

Description

The Central System triggers a message from the Charge Point, but the Charge Point rejects the message.

Purpose

Check whether the Charge Point is able to reject a message triggered by the Central System.

Prerequisite(s)

The Charge Point supports the Remote Trigger feature profile.

Before (Preparations)

Configuration State(s):

  • N/a

Memory State(s):

  • N/a

Reusable State(s):

  • N/a

Scenario Detail(s)

Charge Point (SUT)Central System (Tool)
2. The Charge Point responds with a TriggerMessage.conf OR; with a CallError1. The Central System sends a TriggerMessage.req

Tool validation(s)

Charge Point side:

Step 2:

(Message: TriggerMessage.conf)

  • status is Rejected

Central System side:

Step 1:

(Message: TriggerMessage.req)

  • requestMessage is MeterValues
  • connectorId is configured NumberOfConnectors + 1

Expected result(s) / behaviour

Charge Point side:

The Charge Point does not send the message that was requested by the Central System.

Central System side:

  • N/a