Skip to content
Documentation Menu

TC_055_CSMS — Trigger Message - Rejected

TC_055_CSMS — Trigger Message - Rejected

Source: OCPP 1.6 — Compliancy Testing Tool — Test Case Document (Trial 2025-06, Draft). System Under Test: Central System, page 173.

Identification

FieldValue
Test case nameTrigger Message - Rejected
Test case IdTC_055_CSMS
System under testCentral System

Description

The Central System triggers a message from the Charge Point, but the Charge Point rejects the message.

Purpose

To check whether the Central System is able to handle a reject on a triggered message.

Prerequisite(s)

The Central System supports the Remote Trigger feature profile.

Before (Preparations)

Configuration State(s):

  • N/a

Memory State(s):

  • N/a

Reusable State(s):

  • N/a

Scenario Detail(s)

Charge Point (SUT)Central System (Tool)
2. The Charge Point responds with a TriggerMessage.conf1. The Central System sends a TriggerMessage.req

Tool validation(s)

Charge Point side:

Step 2:

(Message: TriggerMessage.conf) The status is Rejected

Central System side:

Step 1:

(Message: TriggerMessage.req) The requestMessage should be MeterValues

Expected result(s) / behaviour

Charge Point side:

  • N/a

Central System side:

The Central System processes the response from the Charge Point.