TC_055_CSMS — Trigger Message - Rejected
TC_055_CSMS — Trigger Message - Rejected
Source: OCPP 1.6 — Compliancy Testing Tool — Test Case Document (Trial 2025-06, Draft). System Under Test: Central System, page 173.
Identification
| Field | Value |
|---|---|
| Test case name | Trigger Message - Rejected |
| Test case Id | TC_055_CSMS |
| System under test | Central System |
Description
The Central System triggers a message from the Charge Point, but the Charge Point rejects the message.
Purpose
To check whether the Central System is able to handle a reject on a triggered message.
Prerequisite(s)
The Central System supports the Remote Trigger feature profile.
Before (Preparations)
Configuration State(s):
- N/a
Memory State(s):
- N/a
Reusable State(s):
- N/a
Scenario Detail(s)
| Charge Point (SUT) | Central System (Tool) |
|---|---|
| 2. The Charge Point responds with a TriggerMessage.conf | 1. The Central System sends a TriggerMessage.req |
Tool validation(s)
Charge Point side:
Step 2:
(Message: TriggerMessage.conf) The status is Rejected
Central System side:
Step 1:
(Message: TriggerMessage.req) The requestMessage should be MeterValues
Expected result(s) / behaviour
Charge Point side:
- N/a
Central System side:
The Central System processes the response from the Charge Point.