Skip to content
Documentation Menu

TC_064_CSMS — Data Transfer to a Central System

TC_064_CSMS — Data Transfer to a Central System

Source: OCPP 1.6 — Compliancy Testing Tool — Test Case Document (Trial 2025-06, Draft). System Under Test: Central System, page 179.

Identification

FieldValue
Test case nameData Transfer to a Central System
Test case IdTC_064_CSMS
System under testCentral System

Description

The Charge Point sends a vendor specific message to the Central System.

Purpose

To check whether the Central System can reject vendor specific messages.

Prerequisite(s)

The Central System does not support DataTransfer for a specific vendorId.

Before (Preparations)

Configuration State(s):

  • N/a

Memory State(s):

  • N/a

Reusable State(s):

  • N/a

Scenario Detail(s)

Charge Point (SUT)Central System (Tool)
1. The Charge Point sends a DataTransfer.req message with a specific vendorId to the Charge Point.2. The Central System responds with a DataTransfer.conf message.

Tool validation(s)

Charge Point side:

  • N/a

Central System side:

Step 2:

(Message: DataTransfer.conf) The status is Rejected OR UnknownMessageId OR UnknownVendorId Note: The statusAccepted is allowed, but the vendor should be warned about this behaviour.

Expected result(s) / behaviour

Charge Point side:

  • N/a

Central System side:

The Central System does not accept the DataTransfer.req.