TC_B_43_CS — Set new NetworkConnectionProfile - Rejected

TC_B_43_CS — Set new NetworkConnectionProfile - Rejected

Source: OCPP 2.0.1 Part 6 — Test Cases (Core & Advanced Security, FINAL, 2023-06-30) — Functional block B. Provisioning, page 65.

Identification

FieldValue
Test case nameSet new NetworkConnectionProfile - Rejected
Test case IdTC_B_43_CS
Use case Id(s)B09
Requirement(s)B09.FR.02
System under testCharging Station
Functional blockB. Provisioning

Description

The CSMS updates the connection details on the Charging Station. For instance in preparation of a migration to a new CSMS.

Purpose

To verify if the Charging Station is able to reject when the CSMS tries to set a network connection profile containing invalid data.

Prerequisite(s)

N/a

Before (Preparations)

Configuration State:

  • N/a

Memory State:

  • N/a

Reusable State(s):

  • N/a

Main (Test scenario)

Charging StationCSMS
2. The Charging Station responds with a SetNetworkProfileResponse1. The OCTT sends a SetNetworkProfileRequest with:; - configurationSlot is 999; - connectionData.messageTimeout <Configured messageTimeout>; - connectionData.ocppCsmsUrl <Configured ocppCsmsUrl>; - connectionData.ocppInterface <Configured ocppInterface>; - connectionData.ocppVersion OCPP20; - connectionData.securityProfile <Configured securityProfile>

Tool validations

Step 2:

Message SetNetworkProfileResponse

  • status Rejected

Post scenario validations

  • N/a