TC_E_01_CS — Start transaction options - PowerPathClosed
TC_E_01_CS — Start transaction options - PowerPathClosed
Source: OCPP 2.0.1 Part 6 — Test Cases (Core & Advanced Security, FINAL, 2023-06-30) — Functional block E. Transactions, page 122.
Identification
| Field | Value |
|---|---|
| Test case name | Start transaction options - PowerPathClosed |
| Test case Id | TC_E_01_CS |
| Use case Id(s) | E01(S5) |
| Requirement(s) | E01.FR.05, E01.FR.07, E01.FR.10, E01.FR.15, E01.FR.16 |
| System under test | Charging Station |
| Functional block | E. Transactions |
Description
OCPP 2.x.x has a flexible transaction mechanism that allows the transaction start and stop points to be configured differently. This test covers one of the start options.
Purpose
To verify if the Charging Station starts a transaction when the power path has been closed and it has been configured to do so.
Prerequisite(s)
- The Charging Station does NOT have the following configuration; The mutability of TxStartPoint is ReadOnly AND (the value PowerPathClosed is NOT set OR (ParkingBayOccupancy OR EVConnected OR Authorized OR DataSigned), is set).
- If the mutability of TxStartPoint is ReadWrite, then the value PowerPathClosed must be supported.
Before (Preparations)
Configuration State:
- If the mutability of TxStartPoint is ReadWrite then TxStartPoint contains PowerPathClosed
Memory State:
- N/a
Reusable State(s):
- State is Authorized
Main (Test scenario)
| Charging Station | CSMS |
|---|---|
| 1. Execute Reusable State EVConnectedPreSession |
Tool validations
N/a
Post scenario validations
- N/a