TC_E_07_CS — Stop transaction options - PowerPathClosed - Local stop
TC_E_07_CS — Stop transaction options - PowerPathClosed - Local stop
Source: OCPP 2.0.1 Part 6 — Test Cases (Core & Advanced Security, FINAL, 2023-06-30) — Functional block E. Transactions, page 140.
Identification
| Field | Value |
|---|---|
| Test case name | Stop transaction options - PowerPathClosed - Local stop |
| Test case Id | TC_E_07_CS |
| Use case Id(s) | E06(S5) |
| Requirement(s) | E06.FR.06, E06.FR.15 |
| System under test | Charging Station |
| Functional block | E. Transactions |
Description
OCPP 2.x.x has a flexible transaction mechanism that allows the transaction start and stop points to be configured differently. This test covers one of the stop options.
Purpose
To verify if the Charging Station stops a transaction when it is locally stopped by an EV driver and TxStopPoint contains PowerPathClosed.
Prerequisite(s)
- The Charging Station does NOT have the following configuration; The mutability of TxStopPoint is ReadOnly AND (the value PowerPathClosed is NOT set OR Authorized is set).
- If the mutability of TxStopPoint is ReadWrite, then the value PowerPathClosed must be supported.
Before (Preparations)
Configuration State:
- TxStopPoint contains PowerPathClosed
Memory State:
- N/a
Reusable State(s):
- State is EnergyTransferStarted
Main (Test scenario)
| Charging Station | CSMS |
|---|---|
| Manual Action: Present IdToken to stop charging session. | |
| 1. Execute Reusable State StopAuthorized |
Tool validations
N/a
Post scenario validations
- N/a