Skip to content
Documentation Menu

TC_E_22_CSMS — Stop transaction options - EnergyTransfer stopped - SuspendedEV

TC_E_22_CSMS — Stop transaction options - EnergyTransfer stopped - SuspendedEV

Source: OCPP 2.0.1 Part 6 — Test Cases (Core & Advanced Security, FINAL, 2023-06-30) — Functional block E. Transactions, page 397.

Identification

FieldValue
Test case nameStop transaction options - EnergyTransfer stopped - SuspendedEV
Test case IdTC_E_22_CSMS
Use case Id(s)E06(S6)
Requirement(s)E06.FR.07
System under testCSMS
Functional blockE. Transactions

Description

OCPP 2.x.x has a flexible transaction mechanism that allows the transaction start and stop points to be configured differently. This test covers one of the stop options.

Purpose

To verify if the CSMS is able to handle a Charging Station that stops a transaction when the energy transfer stopped by the EV.

Prerequisite(s)

N/a

Before (Preparations)

Configuration State:

  • N/a

Memory State:

  • N/a

Reusable State(s):

  • State is EnergyTransferStarted

Main (Test scenario)

Charging StationCSMS
1. The OCTT sends a TransactionEventRequest; With triggerReason is ChargingStateChanged transactionInfo.chargingState is SuspendedEV transactionInfo.stoppedReason is StoppedByEV eventType is Ended2. The CSMS responds with a TransactionEventResponse

Tool validations

N/a

Post scenario validations

  • N/a