TC_F_01_CS — Remote start transaction - Cable plugin first

TC_F_01_CS — Remote start transaction - Cable plugin first

Source: OCPP 2.0.1 Part 6 — Test Cases (Core & Advanced Security, FINAL, 2023-06-30) — Functional block F. Remote Control, page 173.

Identification

FieldValue
Test case nameRemote start transaction - Cable plugin first
Test case IdTC_F_01_CS
Use case Id(s)F01
Requirement(s)F01.FR.03, F01.FR.04, F01.FR.05, F01.FR.13, F01.FR.17, F01.FR.19, F02.FR.01
System under testCharging Station
Functional blockF. Remote Control

Description

OCPP 2.x.x allows an EV driver to either first connect the EV and EVSE OR wait for/trigger a RequestStartTransactionRequest. Both sequences will result in being able to charge.

Purpose

To verify if the Charging Station is able to start a charging session when the EV driver first connects the EV and EVSE, before receiving a RequestStartTransactionRequest message.

Prerequisite(s)

  • The Charging Station does NOT have a cable lock, which prevents the EV driver to connect the EV and EVSE before authorization.

Before (Preparations)

Configuration State:

  • AuthCtrlr.AuthEnabled is true (If implemented AND ReadWrite) AuthCtrlr.DisableRemoteAuthorization is false (If implemented)

Memory State:

  • N/a

Reusable State(s):

  • State is EVConnectedPreSession

Main (Test scenario)

Charging StationCSMS
1. Execute Reusable State Authorized (remote)
2. Execute Reusable State EnergyTransferStarted

Tool validations

N/a

Post scenario validations