TC_F_01_CS — Remote start transaction - Cable plugin first
TC_F_01_CS — Remote start transaction - Cable plugin first
Source: OCPP 2.0.1 Part 6 — Test Cases (Core & Advanced Security, FINAL, 2023-06-30) — Functional block F. Remote Control, page 173.
Identification
| Field | Value |
|---|---|
| Test case name | Remote start transaction - Cable plugin first |
| Test case Id | TC_F_01_CS |
| Use case Id(s) | F01 |
| Requirement(s) | F01.FR.03, F01.FR.04, F01.FR.05, F01.FR.13, F01.FR.17, F01.FR.19, F02.FR.01 |
| System under test | Charging Station |
| Functional block | F. Remote Control |
Description
OCPP 2.x.x allows an EV driver to either first connect the EV and EVSE OR wait for/trigger a RequestStartTransactionRequest. Both sequences will result in being able to charge.
Purpose
To verify if the Charging Station is able to start a charging session when the EV driver first connects the EV and EVSE, before receiving a RequestStartTransactionRequest message.
Prerequisite(s)
- The Charging Station does NOT have a cable lock, which prevents the EV driver to connect the EV and EVSE before authorization.
Before (Preparations)
Configuration State:
- AuthCtrlr.AuthEnabled is true (If implemented AND ReadWrite) AuthCtrlr.DisableRemoteAuthorization is false (If implemented)
Memory State:
- N/a
Reusable State(s):
- State is EVConnectedPreSession
Main (Test scenario)
| Charging Station | CSMS |
|---|---|
| 1. Execute Reusable State Authorized (remote) | |
| 2. Execute Reusable State EnergyTransferStarted |
Tool validations
N/a
Post scenario validations
- N/a