Skip to content
Documentation Menu

TC_F_27_CSMS — Trigger message - NotImplemented

TC_F_27_CSMS — Trigger message - NotImplemented

Source: OCPP 2.0.1 Part 6 — Test Cases (Core & Advanced Security, FINAL, 2023-06-30) — Functional block F. Remote Control, page 421.

Identification

FieldValue
Test case nameTrigger message - NotImplemented
Test case IdTC_F_27_CSMS
Use case Id(s)F06
Requirement(s)F06.FR.08
System under testCSMS
Functional blockF. Remote Control

Description

The CSMS can request a Charging Station to send Charging Station-initiated messages. In the request the CSMS indicates which message it wishes to receive.

Purpose

To verify if the CSMS is able to handle a Charging Station that does not support the requested message value from a TriggerMessageRequest.

Prerequisite(s)

N/a

Before (Preparations)

Configuration State:

  • N/a

Memory State:

  • N/a

Reusable State(s):

  • N/a

Main (Test scenario)

Charging StationCSMS
2. The OCTT responds with a TriggerMessageResponse; with status NotImplemented1. The CSMS sends a TriggerMessageRequest

Tool validations

N/a

Post scenario validations

  • N/a