TC_G_05_CS — Change Availability Charging Station - Operative to inoperative
TC_G_05_CS — Change Availability Charging Station - Operative to inoperative
Source: OCPP 2.0.1 Part 6 — Test Cases (Core & Advanced Security, FINAL, 2023-06-30) — Functional block G. Availability, page 201.
Identification
| Field | Value |
|---|---|
| Test case name | Change Availability Charging Station - Operative to inoperative |
| Test case Id | TC_G_05_CS |
| Use case Id(s) | G04 |
| Requirement(s) | G04.FR.01, G04.FR.02, G04.FR.03, G04.FR.05, G04.FR.07 |
| System under test | Charging Station |
| Functional block | G. Availability |
Description
This test case describes how the CSMS requests the Charging Station to change the availability from operative to inoperative. A Charging Station is considered Operative when it is charging or ready for charging. A Charging Station is considered Inoperative when it does not allow any charging.
Purpose
To verify if the Charging Station is able to perform the change availability mechanism as described at the OCPP specification.
Prerequisite(s)
n/a
Before (Preparations)
Configuration State:
- N/a
Memory State:
- N/a
Reusable State(s):
- N/a
Main (Test scenario)
| Charging Station | CSMS |
|---|---|
| 1. Execute Reusable State Unavailable |
Tool validations
N/a
Post scenario validations
- A message to report the state of a connector has been received for all connectors.