Skip to content
Documentation Menu

TC_G_10_CS — Change Availability EVSE - Inoperative to inoperative

TC_G_10_CS — Change Availability EVSE - Inoperative to inoperative

Source: OCPP 2.0.1 Part 6 — Test Cases (Core & Advanced Security, FINAL, 2023-06-30) — Functional block G. Availability, page 206.

Identification

FieldValue
Test case nameChange Availability EVSE - Inoperative to inoperative
Test case IdTC_G_10_CS
Use case Id(s)G03
Requirement(s)G03.FR.01, G03.FR.02, G03.FR.03, G03.FR.04
System under testCharging Station
Functional blockG. Availability

Description

This test case covers how the CSMS requests the Charging Station to change the availability of one of the EVSEs from Inoperative to Inoperative. An EVSE is considered Inoperative in status Faulted and Unavailable.

Purpose

To verify if the Charging Station is able to perform the change availability from inoperative to inoperative according to the mechanism as described at the OCPP specification.

Prerequisite(s)

n/a

Before (Preparations)

Configuration State:

  • N/a

Memory State:

  • N/a

Reusable State(s):

  • N/a

Main (Test scenario)

Charging StationCSMS
2. The Charging Station responds with a ChangeAvailabilityResponse1. The OCTT sends a ChangeAvailabilityRequest; with operationalStatus Inoperative and evse.id <Configured evseId>

Tool validations

Step 2:

Message ChangeAvailabilityResponse

  • status Accepted

Post scenario validations

  • A message to report the state of a connector has been received for all connectors.