TC_J_07_CS — Sampled Meter Values - EventType Started - EVSE known
TC_J_07_CS — Sampled Meter Values - EventType Started - EVSE known
Source: OCPP 2.0.1 Part 6 — Test Cases (Core & Advanced Security, FINAL, 2023-06-30) — Functional block J. MeterValues, page 227.
Identification
| Field | Value |
|---|---|
| Test case name | Sampled Meter Values - EventType Started - EVSE known |
| Test case Id | TC_J_07_CS |
| Use case Id(s) | J02 & (E01,E02,E03,E09,E04,E05) |
| Requirement(s) | J02.FR.01,J02.FR.02,J02.FR.03,J02.FR.04,J02.FR.10,E01.FR.09,E02.FR.09,E03.FR.07,E04.FR.05,E05.FR.05 |
| System under test | Charging Station |
| Functional block | J. MeterValues |
Description
The Charging Station samples the electrical meter or other sensor/transducer hardware to provide information about its Meter Values. Depending on configuration settings, the Charging Station will send Meter Values.
Purpose
To verify if the Charging Station is able to send sampled Meter Values when a transaction starts and the EVSE is known, at the TransactionEventRequest with eventType is Started, when it is configured to do so.
Prerequisite(s)
- The Charging Station has an energy meter.
- The Charging Station does NOT have the following configuration; TxStartPoint contains ParkingBayOccupancy
Before (Preparations)
Configuration State:
- TxStartPoint contains EVConnected Note: TxStartPoint contains EVConnected, Authorized, PowerPathClosed, EnergyTransfer AND/OR DataSigned (At least one of these values must be set).
Memory State:
- N/a
Reusable State(s):
- State is ParkingBayOccupied
Main (Test scenario)
| Charging Station | CSMS |
|---|---|
| 1. Execute Reusable State EVConnectedPreSession | |
| 2. Execute Reusable State EnergyTransferStarted |
Tool validations
N/a
Post scenario validations
- The TransactionEventRequest containing eventType Started contains the MeterValue field.
- sampledValue[0].context must be Transaction.Begin
- sampledValue must contain <An element per configured measurand at the SampledDataTxStartedMeasurands. The measurand field may be omitted when the measurand is "Energy.Active.Import.Register">