TC_J_07_CS — Sampled Meter Values - EventType Started - EVSE known

TC_J_07_CS — Sampled Meter Values - EventType Started - EVSE known

Source: OCPP 2.0.1 Part 6 — Test Cases (Core & Advanced Security, FINAL, 2023-06-30) — Functional block J. MeterValues, page 227.

Identification

FieldValue
Test case nameSampled Meter Values - EventType Started - EVSE known
Test case IdTC_J_07_CS
Use case Id(s)J02 & (E01,E02,E03,E09,E04,E05)
Requirement(s)J02.FR.01,J02.FR.02,J02.FR.03,J02.FR.04,J02.FR.10,E01.FR.09,E02.FR.09,E03.FR.07,E04.FR.05,E05.FR.05
System under testCharging Station
Functional blockJ. MeterValues

Description

The Charging Station samples the electrical meter or other sensor/transducer hardware to provide information about its Meter Values. Depending on configuration settings, the Charging Station will send Meter Values.

Purpose

To verify if the Charging Station is able to send sampled Meter Values when a transaction starts and the EVSE is known, at the TransactionEventRequest with eventType is Started, when it is configured to do so.

Prerequisite(s)

  • The Charging Station has an energy meter.
  • The Charging Station does NOT have the following configuration; TxStartPoint contains ParkingBayOccupancy

Before (Preparations)

Configuration State:

  • TxStartPoint contains EVConnected Note: TxStartPoint contains EVConnected, Authorized, PowerPathClosed, EnergyTransfer AND/OR DataSigned (At least one of these values must be set).

Memory State:

  • N/a

Reusable State(s):

  • State is ParkingBayOccupied

Main (Test scenario)

Charging StationCSMS
1. Execute Reusable State EVConnectedPreSession
2. Execute Reusable State EnergyTransferStarted

Tool validations

N/a

Post scenario validations

  • The TransactionEventRequest containing eventType Started contains the MeterValue field.
  • sampledValue[0].context must be Transaction.Begin
  • sampledValue must contain <An element per configured measurand at the SampledDataTxStartedMeasurands. The measurand field may be omitted when the measurand is "Energy.Active.Import.Register">