TC_N_32_CSMS — Clear Customer Information - Clear and no report
TC_N_32_CSMS — Clear Customer Information - Clear and no report
Source: OCPP 2.0.1 Part 6 — Test Cases (Core & Advanced Security, FINAL, 2023-06-30) — Functional block N. Diagnostics, page 475.
Identification
| Field | Value |
|---|---|
| Test case name | Clear Customer Information - Clear and no report |
| Test case Id | TC_N_32_CSMS |
| Use case Id(s) | N10 |
| Requirement(s) | N10.FR.08 |
| System under test | CSMS |
| Functional block | N. Diagnostics |
Description
The CSMS sends a message to the Charging Station to clear IdToken customer information, for example to be compliant with local privacy laws.
Purpose
To verify if the CSMS sends the request correctly.
Prerequisite(s)
n/a
Before (Preparations)
Configuration State:
- N/a
Memory State:
- N/a
Reusable State(s):
- N/a
Main (Test scenario)
| Charging Station | CSMS |
|---|---|
| 2. The OCTT responds with a CustomerInformationResponse; with status Accepted | 1. The CSMS sends a CustomerInformationRequest |
Tool validations
Step 1:
Message CustomerInformationRequest
- report false
- clear true
- idToken.idToken <Configured valid_idtoken_idtoken>
- idToken.type <Configured valid_idtoken_type>
Post scenario validations
- N/a