TC_F_11_CSMS — Trigger message - MeterValues - Specific EVSE

TC_F_11_CSMS — Trigger message - MeterValues - Specific EVSE

Source: OCPP 2.0.1 Part 6 — Test Cases (Core & Advanced Security, FINAL, 2023-06-30) — Functional block F. Remote Control, page 411.

Identification

FieldValue
Test case nameTrigger message - MeterValues - Specific EVSE
Test case IdTC_F_11_CSMS
Use case Id(s)F06
Requirement(s)F06.FR.01,F06.FR.02
System under testCSMS
Functional blockF. Remote Control

Description

The CSMS can request a Charging Station to send Charging Station-initiated messages. In the request the CSMS indicates which message it wishes to receive.

Purpose

To verify if the CSMS is able to trigger the Charging Station to send a MeterValuesRequest for a specific EVSE, using a TriggerMessageRequest.

Prerequisite(s)

N/a

Before (Preparations)

Configuration State:

  • N/a

Memory State:

  • N/a

Reusable State(s):

  • N/a

Main (Test scenario)

Charging StationCSMS
2. The OCTT responds with a TriggerMessageResponse; with status Accepted1. The CSMS sends a TriggerMessageRequest
3. The OCTT sends a MeterValuesRequest; With evseId <Configured evseId> meterValue[0].sampledValue.context Trigger4. The CSMS responds with a MeterValuesResponse

Tool validations

Step 1:

Message: TriggerMessageRequest

  • requestedMessage must be MeterValues
  • evse.id must be <Configured evseId>

Post scenario validations