TC_F_12_CSMS — Trigger message - MeterValues - All EVSE
TC_F_12_CSMS — Trigger message - MeterValues - All EVSE
Source: OCPP 2.0.1 Part 6 — Test Cases (Core & Advanced Security, FINAL, 2023-06-30) — Functional block F. Remote Control, page 412.
Identification
| Field | Value |
|---|---|
| Test case name | Trigger message - MeterValues - All EVSE |
| Test case Id | TC_F_12_CSMS |
| Use case Id(s) | F06 |
| Requirement(s) | F06.FR.01 |
| System under test | CSMS |
| Functional block | F. Remote Control |
Description
The CSMS can request a Charging Station to send Charging Station-initiated messages. In the request the CSMS indicates which message it wishes to receive.
Purpose
To verify if the CSMS is able to trigger the Charging Station to send a MeterValuesRequest for all EVSE, using a TriggerMessageRequest.
Prerequisite(s)
N/a
Before (Preparations)
Configuration State:
- N/a
Memory State:
- N/a
Reusable State(s):
- N/a
Main (Test scenario)
| Charging Station | CSMS |
|---|---|
| 2. The OCTT responds with a TriggerMessageResponse; with status Accepted | 1. The CSMS sends a TriggerMessageRequest |
| 3. The OCTT sends a MeterValuesRequest; With evseId omitted meterValue[0].sampledValue.context Trigger; Note(s):; - This step will be executed for every EVSE. | 4. The CSMS responds with a MeterValuesResponse |
Tool validations
Step 1:
Message: TriggerMessageRequest
- requestedMessage must be MeterValues
Post scenario validations
- N/a