TC_G_20_CSMS — Connector status Notification - Lock Failure
TC_G_20_CSMS — Connector status Notification - Lock Failure
Source: OCPP 2.0.1 Part 6 — Test Cases (Core & Advanced Security, FINAL, 2023-06-30) — Functional block G. Availability, page 431.
Identification
| Field | Value |
|---|---|
| Test case name | Connector status Notification - Lock Failure |
| Test case Id | TC_G_20_CSMS |
| Use case Id(s) | G05 |
| Requirement(s) | G05.FR.03 |
| System under test | CSMS |
| Functional block | G. Availability |
Description
This test case describes how the EV Driver is prevented from starting a charge session at the Charging Station while the Connector is not locked properly.
Purpose
To verify if the CSMS responds on a notifyeventrequest as described at the OCPP specification.
Prerequisite(s)
- N/a
Before (Preparations)
Configuration State:
- N/a
Memory State:
- N/a
Reusable State(s):
- N/a
Main (Test scenario)
| Charging Station | CSMS |
|---|---|
| 1. The OCTT sends a NotifyEventRequest with; - eventData.trigger Delta; - eventData.component.name "ConnectorPlugRetentionLock"; - eventData.variable.name "Problem"; - eventData.actualValue "true" | 2. The CSMS responds with a NotifyEventResponse |
Tool validations
N/a
Post scenario validations
- N/a