TC_J_01_CSMS — Clock-aligned Meter Values - No transaction ongoing
TC_J_01_CSMS — Clock-aligned Meter Values - No transaction ongoing
Source: OCPP 2.0.1 Part 6 — Test Cases (Core & Advanced Security, FINAL, 2023-06-30) — Functional block J. MeterValues, page 432.
Identification
| Field | Value |
|---|---|
| Test case name | Clock-aligned Meter Values - No transaction ongoing |
| Test case Id | TC_J_01_CSMS |
| Use case Id(s) | J01 |
| Requirement(s) | J01.FR.18 |
| System under test | CSMS |
| Functional block | J. MeterValues |
Description
The Charging Station samples the electrical meter or other sensor/transducer hardware to provide information about its Meter Values. Depending on configuration settings, the Charging Station will send Meter Values.
Purpose
To verify if the CSMS is able to handle a Charging Station sending clock-aligned Meter Values, when there is no ongoing transaction.
Prerequisite(s)
N/a
Before (Preparations)
Configuration State:
- N/a
Memory State:
- N/a
Reusable State(s):
- N/a
Main (Test scenario)
| Charging Station | CSMS |
|---|---|
| 1. The OCTT notifies the CSMS about its measured Meter Values.; Message: MeterValuesRequest; - timestamp <The intervals between the timestamps of the received Meter Value messages equals the _<Configured clock-aligned Meter Values interval>.; - sampledValue.context is Sample.Clock; Message: NotifyEventRequest; - timestamp <The intervals between the timestamps of the received Meter Value messages equals the _<Configured clock-aligned Meter Values interval>.; - trigger is Periodic; - component.name is FiscalMetering; Note(s):; - This step will be executed every _<Configured clock- aligned Meter Values interval>; - This step will be executed for evseId=0 and all configured EVSE.; - The OCTT will end the testcase after it has send three Meter Value messages. | 2. The CSMS responds accordingly. |
Tool validations
N/a
Post scenario validations
- N/a