TC_J_02_CSMS — Clock-aligned Meter Values - Transaction ongoing

TC_J_02_CSMS — Clock-aligned Meter Values - Transaction ongoing

Source: OCPP 2.0.1 Part 6 — Test Cases (Core & Advanced Security, FINAL, 2023-06-30) — Functional block J. MeterValues, page 433.

Identification

FieldValue
Test case nameClock-aligned Meter Values - Transaction ongoing
Test case IdTC_J_02_CSMS
Use case Id(s)J01
Requirement(s)J01.FR.18
System under testCSMS
Functional blockJ. MeterValues

Description

The Charging Station samples the electrical meter or other sensor/transducer hardware to provide information about its Meter Values. Depending on configuration settings, the Charging Station will send Meter Values.

Purpose

To verify if the CSMS is able to handle a Charging Station sending clock-aligned Meter Values, when there is an ongoing transaction.

Prerequisite(s)

N/a

Before (Preparations)

Configuration State:

  • N/a

Memory State:

  • N/a

Reusable State(s):

  • State is EnergyTransferStarted for <Configured evseId>

Main (Test scenario)

Charging StationCSMS
1. The OCTT notifies the CSMS about its measured Meter Values.; Message: MeterValuesRequest; - timestamp <The intervals between the timestamps of the received Meter Value messages equals the configured clock-aligned Meter Values interval>.; - sampledValue.context is Sample.Clock; Message: NotifyEventRequest; - timestamp <The intervals between the timestamps of the received Meter Value messages equals the configured clock-aligned Meter Values interval>.; - trigger is Periodic; - component.name is FiscalMetering; Note(s):; - This step will be executed every _<Configured clock- aligned Meter Values interval>; - This step will be executed for evseId=0 and all configured idle EVSE.2. The CSMS responds accordingly.
3. The OCTT sends a TransactionEventRequest; With triggerReason is MeterValueClock eventType is Updated timestamp <The intervals between the timestamps of the received Meter Value messages equals the configured clock-aligned Meter Values interval>. sampledValue.context is Sample.Clock; Note(s):; - This step will be executed every _<Configured clock- aligned Meter Values interval>; - The OCTT will end the testcase after the <Configured transaction duration> is reached.4. The CSMS responds with a TransactionEventResponse

Tool validations

N/a

Post scenario validations

  • N/a