TC_J_08_CSMS — Sampled Meter Values - Context Transaction.Begin - EVSE not known
TC_J_08_CSMS — Sampled Meter Values - Context Transaction.Begin - EVSE not known
Source: OCPP 2.0.1 Part 6 — Test Cases (Core & Advanced Security, FINAL, 2023-06-30) — Functional block J. MeterValues, page 438.
Identification
| Field | Value |
|---|---|
| Test case name | Sampled Meter Values - Context Transaction.Begin - EVSE not known |
| Test case Id | TC_J_08_CSMS |
| Use case Id(s) | J02 |
| Requirement(s) | J02.FR.19 |
| System under test | CSMS |
| Functional block | J. MeterValues |
Description
The Charging Station samples the electrical meter or other sensor/transducer hardware to provide information about its Meter Values. Depending on configuration settings, the Charging Station will send Meter Values.
Purpose
To verify if the CSMS is able to handle a Charging Station sending start sampled Meter Values, when a transaction starts.
Prerequisite(s)
N/a
Before (Preparations)
Configuration State:
- N/a
Memory State:
- N/a
Reusable State(s):
- N/a
Main (Test scenario)
| Charging Station | CSMS |
|---|---|
| 1. Execute Reusable State Authorized | |
| 2. Execute Reusable State EVConnectedPreSession; - The TransactionEventRequest contains the MeterValue field.; - sampledValue.context is Transaction.Begin | |
| 3. Execute Reusable State EnergyTransferStarted |
Tool validations
N/a
Post scenario validations
- N/a