Skip to content
Documentation Menu

TC_J_08_CSMS — Sampled Meter Values - Context Transaction.Begin - EVSE not known

TC_J_08_CSMS — Sampled Meter Values - Context Transaction.Begin - EVSE not known

Source: OCPP 2.0.1 Part 6 — Test Cases (Core & Advanced Security, FINAL, 2023-06-30) — Functional block J. MeterValues, page 438.

Identification

FieldValue
Test case nameSampled Meter Values - Context Transaction.Begin - EVSE not known
Test case IdTC_J_08_CSMS
Use case Id(s)J02
Requirement(s)J02.FR.19
System under testCSMS
Functional blockJ. MeterValues

Description

The Charging Station samples the electrical meter or other sensor/transducer hardware to provide information about its Meter Values. Depending on configuration settings, the Charging Station will send Meter Values.

Purpose

To verify if the CSMS is able to handle a Charging Station sending start sampled Meter Values, when a transaction starts.

Prerequisite(s)

N/a

Before (Preparations)

Configuration State:

  • N/a

Memory State:

  • N/a

Reusable State(s):

  • N/a

Main (Test scenario)

Charging StationCSMS
1. Execute Reusable State Authorized
2. Execute Reusable State EVConnectedPreSession; - The TransactionEventRequest contains the MeterValue field.; - sampledValue.context is Transaction.Begin
3. Execute Reusable State EnergyTransferStarted

Tool validations

N/a

Post scenario validations

  • N/a