Skip to content
Documentation Menu

TC_J_09_CSMS — Sampled Meter Values - EventType Updated

TC_J_09_CSMS — Sampled Meter Values - EventType Updated

Source: OCPP 2.0.1 Part 6 — Test Cases (Core & Advanced Security, FINAL, 2023-06-30) — Functional block J. MeterValues, page 439.

Identification

FieldValue
Test case nameSampled Meter Values - EventType Updated
Test case IdTC_J_09_CSMS
Use case Id(s)J02
Requirement(s)J02.FR.19
System under testCSMS
Functional blockJ. MeterValues

Description

The Charging Station samples the electrical meter or other sensor/transducer hardware to provide information about its Meter Values. Depending on configuration settings, the Charging Station will send Meter Values.

Purpose

To verify if the CSMS is able to handle a Charging Station sending sampled Meter Values, when there is an ongoing transaction.

Prerequisite(s)

N/a

Before (Preparations)

Configuration State:

  • N/a

Memory State:

  • N/a

Reusable State(s):

  • State is EnergyTransferStarted

Main (Test scenario)

Charging StationCSMS
1. The OCTT sends a TransactionEventRequest; With triggerReason is MeterValuePeriodic eventType is Updated timestamp <The intervals between the timestamps of the received Meter Value messages equals the configured sampled Meter Values interval>. sampledValue.context is Sample.Periodic; Note(s): _- This step will be executed every _<Configured sampled Meter Values interval>; - The OCTT will end the testcase after three MeterValues.2. The CSMS responds with a TransactionEventResponse

Tool validations

N/a

Post scenario validations

  • N/a