Skip to content
Documentation Menu

TC_J_10_CSMS — Sampled Meter Values - EventType Ended

TC_J_10_CSMS — Sampled Meter Values - EventType Ended

Source: OCPP 2.0.1 Part 6 — Test Cases (Core & Advanced Security, FINAL, 2023-06-30) — Functional block J. MeterValues, page 440.

Identification

FieldValue
Test case nameSampled Meter Values - EventType Ended
Test case IdTC_J_10_CSMS
Use case Id(s)J02
Requirement(s)J02.FR.19
System under testCSMS
Functional blockJ. MeterValues

Description

The Charging Station samples the electrical meter or other sensor/transducer hardware to provide information about its Meter Values. Depending on configuration settings, the Charging Station will send Meter Values.

Purpose

To verify if the CSMS is able to handle a Charging Station sending sampled Meter Values, when a transaction ends.

Prerequisite(s)

N/a

Before (Preparations)

Configuration State:

  • N/a

Memory State:

  • N/a

Reusable State(s):

  • State is EnergyTransferStarted

Main (Test scenario)

Charging StationCSMS
1. Execute Reusable State EVDisconnected; - The TransactionEventRequest containing eventType Ended contains the MeterValue field.; - timestamp <The intervals between the timestamps of the received Meter Value messages equals the configured value at configured clock-aligned Tx ended Meter Values interval>.; - sampledValue.context is Sample.Periodic AND the last one has Transaction.End; Note(s):; - This step will be executed after the <Configured transaction duration> is reached.; - This causes the transaction to stop.

Tool validations

N/a

Post scenario validations

  • N/a